Sign In | Join Free | My remastersys.com
China WWINBEAUTY logo
WWINBEAUTY
Beautify your life, and create a win-win for you and us
Site Member

7 Years

Home > Tattoo Removal Laser >

2000MJ Touch screen Q switched nd yag laser beauty machine tattoo removal Scar Acne remova

WWINBEAUTY

2000MJ Touch screen Q switched nd yag laser beauty machine tattoo removal Scar Acne remova

Place of Origin : China

Brand Name : WWINBEAUTY

Certification : CE

MOQ : 1 set

Price : 1200USD

Packaging Details : W/C

Delivery Time : 5 workdays

Payment Terms : T/T, paypal

Supply Ability : 600sets per month

Contact Now

Working Principle:
Laser technology has been greatly improved with the ability to treat melanocytic lesions and tattoos with the rapidly pulsed
Q-switchneodymium: yttrium-aluminium garnet (Nd: YAG) laser.The energy of Q-switched ND:YAG laser can be absorbed by
the blue and black melanin.The melanin will be fragmented so small that they can be metabolized by the lymphatic system or egested out of the body. Thus the tattoo or other pigmentations will be removed without damage to normal tissue. The treatment is safe and convenient without downtime and side effects.

Photos:



Application & Cautions:
1)Treatmentfor tattoo in eyebrow
Customer could not open eyes during the treatment.The operator should adjust energy according to depth of tattoo color, hold the handle and move it to treatmentarea slowly to make the customer feel acceptable in mentally. Right now, the speed of flash could be set 3HZ, keep head of the handle a two-finger distance totreatment area, start treatment from head of eyebrow to end of eyebrow. It isneeded to treat again in 5-10 minutes if the color of tattoo re-appear.
2)Eye line removal
The speed of flashes could be set 4-5HZ,adjust the energy of light to minimum energy, keep a one-finger distance between the head of handle and the treatment area.The operator should strictly protect customers` eyes with panel for eyelid ormedical pledget (panel for eyelid)of 25px depth.
Treatment should be started from down eye line.The customer should deeply close eyes and keep eyeball up-sight inside. The operator should press the pledget (panelfor eyelid) with forefinger and push up eyelid, peel down eyelid with middlefinger to bare the eye line, treat it with flashes of 4-5Hz. Then, treat up eyeline. Also customer should close eyes and keep eyeball down-sight inside.The operator should press the pledget (panel for eyelid) with middle finger andpush eyelid down, push eyelid up with forefinger to bare the eye line, treat itwith flashes of 4-5Hz.
3)Lip line removal
The speed of flashes could be set 5Hz,keep a 3/4 finger distance between head of handle and treatment area. It is better to remove black, coffee, deep, redand brown lip line with 1064nm head at first time and then, treat again with 532 nm head.
Notice: All tattoos in lip should be treated in 6 months after making, or tattoo removal treatment will fail. It should have 45-60 days interval to continuenext treatment until remove all.
4)Tattoo removal
The speed of flashes could be set 3Hz/5Hz.It is better to use high energy fortreatment until treatment area seeps a little blood. It should have 45-90 days interval to continue next treatment until all tattoos are removed.
5)Spot and nevus removal
The speed of flashes could be set 3Hz/5Hz.Keep 3-4 fingers distance between the head of handle and the treatment area. It is better to use high energy for treatment until treatment area seeps a little blood. It is advised to use 1064nm head for normal spot and nevus treatment, but for deep color spot and nevus,it is better to use 532nm head for treatment. It should have a 15-30 days interval to continue next treatment until remove all.
6)Birthmark removal
The speed of flashes could be set 3Hz/5Hz.It is better to use high energy fortreatment until treatment area seeps a little blood. It is advised to use 1064nm head for birthmark treatment, but for red and deep color birthmark, it is better to use 532nm head for treatment. It should have 45-90 days intervalto continue.

Treatment:

Treatments

Treatment course required

Treatment course interval

Remark (requirements in surgery)

Birthmark,nevus/mole

3-7 times

45-90 days

Blood infiltration is necessary

Freckle, age spot

1-4 times

15-30 days

Blood infiltration is fine on wounds

Tattoos

1-4 times

30-60 days

Blood infiltration is fine on wounds

Lip line (red dyed lip)

1-3 times

15-45 days

By 532nm filter

Eyebrow-embroidery

1-3 times

45-60 days

Eyebrow blow, eyeball protection

eyebrow-embroidery

1 –2 times

30-60 days

Eyebrow blow, eyeball protection

Specifications:

Laser typeSapphire Q-Switch / YAG Laser
Wave lengthwavelength 1064nm & 532nm &1320nm
Width of pulse3.5-10ns
Spots Size1-7mm
Pulse energy20-2000mj
Pulse rate1-10Hz
Net weight20kg
Voltage220V / 110V / 12A 50Hz(60Hz)
Cooling systemWind + water


Cheap 2000MJ Touch screen Q switched nd yag laser beauty machine tattoo removal Scar Acne remova for sale

2000MJ Touch screen Q switched nd yag laser beauty machine tattoo removal Scar Acne remova Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: WWINBEAUTY
*Subject:
*Message:
Characters Remaining: (0/3000)